5-4
Entering Z Calibration values manually (Firmware version 9.1 or newer)
Z tip to tip (ZT2T)
ZT2T is the Z distance from the model tip to the support tip. A positive ZT2T means the
support tip is higher than the model tip. If a support layer on top of model is too thick, add
0.010” to the ZT2T. If a model layer does not stick to supports, subtract 0.010” from the
ZT2T.
If unable to calibrate automatically, this value may need to be set to default in order
to proceed with automatic calibration. The default value is 0.0000”.
1.
While the printer is at
Idle
, enter standby mode by pressing the
Standby...
button.
2.
Enter the Service Calibration menu by pressing the following button sequence on the
display panel:
3,2,3,3,1
. See
3.
Press the
Edit Configuration
button.
4.
Press the
Next...
button.
5.
Press the
Next...
button.
6.
Press the
ZT2T
(Z tip to tip) button.
7.
Enter the calibration value by pressing the
Increment
,
Decrement
and
Next Digit
buttons.
8.
When finished, press
Done...
9.
Press the
Next...
button until you reach the last page.
10.
Press the
Done...
button.
11.
Press the
Save and reboot
button.
12.
The printer will reboot and return to idle.
13.
Perform automatic Z calibration. See
Note:
The value for ZT2T must be between -0.0500” and 0.0500”.
Summary of Contents for uPrint
Page 1: ...uPrint and uPrint Plus uPrint SE and uPrint SE Plus Service Manual Part No 209010 0001 Rev D...
Page 11: ...1 2...
Page 35: ...2 24...
Page 179: ...4 132 Figure 4 231 uPrint Plus and uPrint SE Plus measurement points and worksheet BL FL FR BR...
Page 207: ...4 160 Figure 4 275 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Page 267: ...5 58...
Page 343: ...6 76...
Page 359: ...7 16...
Page 373: ...8 14...