6-18
14,69 Abort: XY PMD Read Check-
sum error
1.
If error occurs more than once a month replace the controller board.
14,70 Abort: XY PMD Write Check-
sum error
1.
If error occurs more than once a month replace the controller board.
14,71 Abort: Z PMD Read Checksum
error
1.
If error occurs more than once a month replace the controller board.
14,72 Abort: Z PMD Write Checksum
error
1.
If error occurs more than once a month replace the controller board.
14,73 Abort: Head TC Board Config-
uration error
Not used on uPrint, uPrint SE, uPrint Plus and uPrint SE Plus printers.
14,74 Unexpected contact with
unknown limit.
1.
Power cycle machine - remember to move head away from switches.
2.
Using LED's check to see limit box toggles when switch is activated. If
not, check switch and/or umbilical cable for X, Y cable for Y.
3.
X errors - Check pins and re-seat connector J505 on the I/O Card. Y
errors - Check pins and re-seat connector J503 on the I/O Card.
14,75 Unknown
1.
No error code associated with an error.
14,76 Software bug
1.
Cycle power.
14,77 Buffer is larger than the data
14,78 Buffer is smaller than the data
1.
Cycle power.
2.
Replace Single Board Computer.
3.
Replace Controller Board.
14,79 Run-time error
1.
Cycle power.
2.
Check .cfg File for other errors.
3.
Replace Single Board Computer.
4.
Replace Controller Board.
14,80 Index out of bounds
1.
Cycle power.
14,81 Invalid argument
1.
Cycle power.
14,82 Invalid channel
1.
Cycle power.
14,83 Invalid command
1.
Cycle power.
14,84 Invalid command opCode
1.
Cycle power.
14,85 The operation is not imple-
mented
Software error; will not be displayed.
14,86 Time-out
1.
Cycle power.
2.
If CFG file contains: Time-out due to position
- Replace Toggle Plate Assembly.
3.
If CFG file contains: Time-out due to temperature
- Replace Toggle Plate Assembly.
- Replace TC Amp Board.
4.
Replace Controller Board.
14,87 Resource already in use
1.
Cycle power.
14,88 The dual-port memory is cor-
rupted
1.
Cycle power.
14,89 No valid ISR callback routine
set
1.
Cycle power.
14,90 An internal queue has over-
flowed
1.
Cycle power.
14,91 Address not properly aligned
1.
Cycle power.
14,92 Message too big for queue
1.
Cycle power.
14,93 Data unit size violation
1.
Cycle power.
14,94 Checksum bad
1.
Cycle power.
2.
Check 5/12 VDC power (5 and 12VDC LEDs will repeatedly dim).
Replace 5/12 VDC power supply.
3.
If error code is displayed again within 3 months, replace Controller
Board.
14,95 PMD Host IO Error
1.
Cycle power.
Code
Description
Corrective Actions
Summary of Contents for uPrint
Page 1: ...uPrint and uPrint Plus uPrint SE and uPrint SE Plus Service Manual Part No 209010 0001 Rev D...
Page 11: ...1 2...
Page 35: ...2 24...
Page 179: ...4 132 Figure 4 231 uPrint Plus and uPrint SE Plus measurement points and worksheet BL FL FR BR...
Page 207: ...4 160 Figure 4 275 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Page 267: ...5 58...
Page 343: ...6 76...
Page 359: ...7 16...
Page 373: ...8 14...