uPrint/uPrint SE Service Manual
5-5
XY Tip Calibration
Typical XY calibration
1.
Press
Maintenance.
2.
Press
Machine.
3.
Press
Tip.
4.
Press
Calibrate XY.
5.
Press
Start Part.
The printer will automatically build a XY Calibration part. (Build time is
approximately 10 minutes).
6.
When the XY Calibration part is complete the printer will display
Remove Part and Select
XY Adjustment - X:0, Y:0
7.
Remove the XY Tip Calibration part from the printer.
8.
Inspect the part and calibrate the X and Y axes as follows. See
A.
Use the magnifier from the Startup Kit to view the support road.
B.
Identify the location on the +X
or
–X side of the part where the support road is
best centered within the model boundaries.
C.
Read the number closest to this location. This is the required X Tip Offset
adjustment, in mils. If the number is on the -X side, a negative offset is required.
D.
Select
Increment
or
Decrement
to input the X offset adjustment - the value will
change in the upper display window (by default, the printer will be ready to
accept the X value).
E.
Once you have entered the X offset value,
Select Y
and repeat the procedure for Y
Offset value.
9.
Select
Done
after you have input the X and Y tip offsets. The printer will return to
Maintenance
.
10.
Repeat steps 1-9 to verify proper calibration.
Figure 5-279: Example XY Tip Offset Part.
This example requires an adjustment of X = + 2 mils, Y = - 4 mils
Note:
Unusual circumstances may require that the XY tip calibration values be
entered manually. To change these values, see
Summary of Contents for uPrint
Page 1: ...uPrint and uPrint Plus uPrint SE and uPrint SE Plus Service Manual Part No 209010 0001 Rev D...
Page 11: ...1 2...
Page 35: ...2 24...
Page 179: ...4 132 Figure 4 231 uPrint Plus and uPrint SE Plus measurement points and worksheet BL FL FR BR...
Page 207: ...4 160 Figure 4 275 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Page 267: ...5 58...
Page 343: ...6 76...
Page 359: ...7 16...
Page 373: ...8 14...