7-12
6.
Verify the tip is fully inserted into the heater block and that the stainless steel shield is
aligned. See
7.
Use 7/64 T-Handle Allen wrench to firmly tighten the heater block clamp screws. See
Figure 7-413: Installation Examples
8.
Repeat steps 3 through 7 for the other tip if necessary.
9.
Install a new tip shield by pushing it over the exposed tip, keeping the slotted end
toward the back of the head. See
Figure 7-414: Tip shield installation
Note:
Make sure the tip remains all the way up against the heater block as you
tighten the screws.
Note:
Tip shield should be flush with the tip plate as shown in
INCORRECT -
Shield
interference
INCORRECT -
Tip not seated
CORRECT
Summary of Contents for uPrint