Installing the X motor
1.
Place the X belt around the X motor pulley.
2.
Align the X motor into the X motor mounting bracket making sure the X motor cable
faces the front of the printer.
3.
Using a
9
⁄
64
” allen wrench, reinstall the 4 X motor mounting screws.
4.
Align the X motor mounting bracket with the mounting holes.
5.
Using a
5
⁄
16
” nut driver or standard screwdriver, reinstall the 4 X motor mounting
bracket mounting screws.
6.
Align the X motor energy chain mounting bracket with the mounting holes.
7.
Using a
5
⁄
16
” nut driver or standard screwdriver, reinstall the 2 X motor energy chain
mounting screws.
8.
Reconnect the X motor cable.
9.
Reinstall a wire tie around the X motor cable connector. See
Figure 4-166: X motor wire tie locations
10.
Move the Head Assembly to the full right travel position within the build envelope (as
viewed from the front of the printer).
11.
Insert the zero gauge block into the gauge. See
12.
Loosen the adjustment screw and slide the dial indicator assembly up or down to set the
‘zero’ reading: The large hand should be on 0 and the small hand on 5.
13.
Tighten the adjustment screw (do not over tighten the screw) and recheck the reading.
14.
Remove the zero block gauge block from the fixture.
Reinstall wire
tie
Summary of Contents for uPrint
Page 1: ...uPrint and uPrint Plus uPrint SE and uPrint SE Plus Service Manual Part No 209010 0001 Rev D...
Page 11: ...1 2...
Page 35: ...2 24...
Page 179: ...4 132 Figure 4 231 uPrint Plus and uPrint SE Plus measurement points and worksheet BL FL FR BR...
Page 207: ...4 160 Figure 4 275 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Page 267: ...5 58...
Page 343: ...6 76...
Page 359: ...7 16...
Page 373: ...8 14...