Chapter 4 Positioning Parameter & Operation Data
4-20
2) Method by in-position signal
a) In case that in-position signal becomes ON before positioning is completed
Positioning complete signal will be on when reaching goal and positioning is completed
b) In case In-positioning signal becomes on after positioning is completed.
After reaching goal and positioning is completed, wait until In-position signal becomes on. When In-
position signal becomes on, positioning complete signal will be on.
Speed
Start
In operation
Command
in-position
width
Time
In-position
signal
Positioning
completion
Command
Speed
Current
Speed
Speed
Start
In-operation
Command
in-position
width
Time
In-position
signal
Positioning
completion
Command
speed
Current
speed