Chapter 6 Command
6-12
6.3.6 Simultaneous Start Step Setting (Command : XSWR)
(1) Program
(2) Description
Refer to the chapter 6.3.5 for device description.
Comman
d
XSWR
Simultaneous start step setting
Operand
OP1
Slot
Constant
WOR
D
Slot no. installed with positioning module
OP2
Axis
PMLK,constant,D,Z,R,ZR WOR
D
Command axis
XBF-PN04B: 1axis~4axis
XBF-PN08B:1axis~8axis
OP3
Device
PMLK,constant,D,Z,R,ZR WOR
D
The device leading no. has simultaneous
start step no.
OP4 Number of
step
PMLK,constant,D,Z,R,ZR WOR
D
The number of step to use.
※
PMLK means P, M, L and K areas.
(a) In the example program, axis 1, axis 2, axis5 operate no.1 step, no.5 step, no.10 step respectively.
(c) To set steps of axis for simultaneous start, use XSWR command or PUT/PUTP command to set
simultaneous start step no. on s imultaneous start step memory address. This must be c omplete before
simultaneous start executes.
(c) When using PUT command to set simultaneous start, refer to the memory address of “5.1.3 Simultaneous