Chapter 8 Program
8-12
(3) Inching Operation
(a) Condition of Inching Operation
Condition of Inching Operation Command (XINCH)
(b) Axis Ready
If communication between the positioning module and the servo driver is normal, the signal corresponding to
each axis will be on.
(c) Operating state by axis
According to exercise from “Chapter 8.1.2 Current State Reading,” it is a signal of “Inching Operating” for each
axis. It turns on when it is operating. Inching Operation can not be c onfigured while it is running hence
configuration will only be configured when it is not running. If you execute Inching Operation while it is running,
the “error 401” would be appeared.
Moves 1-axis as many as D01000
Moves 2-axis as many as D01002
Moves 3-axis as many as D01004
Moves 4-axis as many as D01006
Moves 5-axis as many as D01008
Moves 6-axis as many as D01010
Moves 7-axis as many as D01012
Moves 8-axis as many as D01014
(a) Condition for inching operation
(b) Axis ready
(c) Operation state
(d) Error state
(e) Servo On signal
(h) Inching moving amount
(f) Position of the module
(g) Command axis
Summary of Contents for XBF-PN04B
Page 1: ...Programmable Logic Controller Positioning Module EtherCAT XGB Series XBF PN04B XBF PN08B ...
Page 626: ...Chapter 9 Functions BPS37 setup RS232 and PC connection BPS37 option board LED 9 193 ...
Page 796: ...Appendix3 Dimension A3 1 Appendix 3 Dimension Appendix 3 1 Dimension of XBF PN04B PN08B ...