Chapter 8 Program
8-87
(2) Disconnecting servo driver
(a) Condition for servo disconnection
Condition to execute Servo disconnection command (XPM_DCON)
(b) Link up/down information
If you use Link up down information as input condition point of servo connection command, you can execute
the command only when network cable is actually connected.
(c) Address of Positioning Module
Before operation, you need t o configure its position by numbers. In this example, Positioning Module is
installed at the 3 slot.
(d) State of Operation complete
If function block is completed without error, “1” will be outputted and m aintain “1” until the next operation. If
error occurred, “0” will be outputted.
(e) Error State
This is the area that output error no. if there are errors in operation of function block.
(f) Axis ready state
If disconnection with servo driver is complete, corresponding signal will be off. In the example, we assume that
two axes are connected to the module. Set the only connected axis according to system. If disconnection is
complete, corresponding signal will be off and reset the condition for servo disconnection.
_0003_LINK
UP_INFO
(a) Condition for servo disconnection
(b) Link up/down information
(f) Axis ready state
(c) Position of the module
(d) Completion state
(e) Error state