Chapter 6 Command
6-71
6.3.45 Point Start (Command : XPST)
(1) Program
(2) Description
Device
Description
M00031
axis1 point start step data setting input
M00032
axis1 point start input
U02.00.0
axis1 ready
D00000.0
axis1 operating state
D00000.1
axis1 error state
D03000
Point start step data setting leading
device
Comman
d
XPST
Point operation
Operand
OP1
Slot
Constant
WOR
D
Slot No. installed with positioning
module
OP2
Axis
PMLK,constant,D,Z,R,ZR WOR
D
Command axis
XBF-PN04B: 1axis~4axis
XBF-PN08B:1axis~8axis
OP3
Point
operation No. PMLK,constant,D,Z,R,ZR
WOR
D
Point operation step No. (1~20)
※
PMLK means P, M, L and K areas.
(a) This is the command that execute point start of command axis.
(b) It is unavailable to be executed when the axis is operating.
(c) It is able to set maximum 20 point start step.
(d) Step data must be set in point start data area before execute point start. For the point start step data setting,
refer to the next page about XPWR command.
(d) For the detail description about operation of point start, refer to “9.2.18 positioning start (4) Point start”.
(f) The example program sets 10 poi nt steps from D03000 on ax is1 and ex ecutes point start to 5 poi nt step
which already set.