Chapter 6 Command
6-19
6.3.13 Skip Operation (Command : XSKP)
(1) Program
(2) Description
Device
Description
M0000B
axis1 skip operation input
U02.00.0
axis1 ready
D00000.0
axis1 in operation
D00000.1
axis1 error state
Command
SKP
Skip operation
Operand
OP1 Slot
Constant
WOR
D
Slot No. installed with positioning
module
OP2 Axis PMLK,constant,D,Z,R,ZR
WOR
D
Command axis
XBF-PN04B: 1axis~4axis
XBF-PN08B:1axis~8axis
※
PMLK means P, M, L and K areas.
(a) This ends and stops the operation of step which is in operation currently and then continues to operate the
next step.
(b) For the details description of skip operation, refer to “9.5.3 Skip Operation.
(c) D device signal (axis1 in Operation, etc) which used in the example above is an assumption that saving the
axis state value in D device area with XSRD command.