Chapter 6 Command
6-78
6.3.50 Servo On (Command: XSVON)
(1) Program
(2) Description
Device
Description
M00036
Servo On input
U02.00.0
Axis1 ready
D00000.0 Axis1 in operation
D00000.1 Axis1 error
D00003.9 Axis1 servo on signal
Comman
d
XSVON
Servo Disconnection
Operand
OP1 Slot
Constant
WOR
D
Slot No. installed with positioning module
OP2 Axis
PMLK,constant,D,Z,R,ZR
WOR
D
Command axis
XBF-PN04B: 1axis~4axis
XBF-PN08B:1axis~8axis
※
PMLK means P, M, L and K areas.
(a) This is the command that turns on t he designated servo driver among servo drivers connected to the
positioning module
(b) In order to start the motor, “Servo On” signal should be on.
(c) In the above example, it gives “Servo On” command to 1-axis.