Chapter 9 Functions
9-146
9.5.2. Continuous Operation
Execute positioning control changing the current operation step no. to the next one.
(1) Characteristics of Control
(a) When continuous operation command is executed, operating speed is changed into the speed of next
operation step directly.
(b) This command may be used in End, Go on, Continuous mode and used at Acc.,Dec.,Steady speed section.
(c) If continuous operation command is executed in operation, the current operation step no. is changed to the
next step no. and keep operating.
(d) There are differences of operation depending on between absolute coordinates and relative coordinates.
(2) Operation timing
B
Time
ON
Speed
Start
In operation
In operation
ON
Operation mode:
Singular, End
Step no. : 2
Operation mode :
Singular, Continuous
Step no. : 1
Position P1
Time
Speed
ON
ON
Time
ON
Speed
Start
Continuous
operation
command
In operation
In operation
ON
Operation mode:
Singular, End
Step no. : 2
Operation mode :
Singular, Continuous
Step no. : 1
Time
Speed
ON
ON
A
Position P2
Position P1
Position P2
Position P1
Position
P1+P2
Position P1
Position
P1+P2
Continuous
operation
command
Operation mode:
Singular, End
Step no. : 2
Operation mode:
Singular, End
Step no. : 2
Operation mode :
Singular, Continuous
Step no. : 1
Operation mode :
Singular, Continuous
Step no. : 1
Operation on absolute coordinates
Operation on relative coordinates
Not Use Co
ninuous Oper
ation
Use Con
tinuous Operatio
n
■ The goal positions of continuous operation on absolute coordinates are same, so the goal position is the same
as the position before and after continuous operation. Therefore, the current position positioned by continuous
operation is P2. (A area and B area both are same size)
■ When continuous operation is executed on relative coordinates, the movement amount between current
position and goal position is the real goal position. Therefore, the goal position is different from the one without
continuous operation. The position positioned by continuous operation is P1 + P2.