Chapter 6 Command
6-47
6.3.33 Set Extended Parameter (Command : XSEP)
(1) Program
(2) Description
Device
Description
M00021
axis1 extended parameter setting input
U02.00.0 axis1 ready
D00000.0 axis1 in operation
D00000.1 axis1 error state
D02100
Parameter value
D02102
Parameter items
Comman
d
XSEP
Extended parameter Teaching
Operand
OP1
Slot
Constant
WOR
D
Slot No. installed with positioning
module
OP2
Axis
PMLK,constant,D,Z,R,ZR WOR
D
Command axis
XBF-PN04B: 1axis~4axis
XBF-PN08B:1axis~8axis
OP3 Parameter
value
PMLK,constant,D,Z,R,ZR
DINT Parameter value to change
OP4 Parameter
item
PMLK,constant,D,Z,R,ZR WOR
D
Parameter item to change (1~2, 4~19)
OP5
Setting
Method
PMLK,constant,D,Z,R,ZR WOR
D
0: RAM setting, 1: ROM setting
※
PMLK means P, M, L and K areas.
(a) This is the command that changes the value of the item (OP4) which already set among basic parameter
items to setting value (OP3). In the case of RAM setting by the setting method (OP5), the changed value is
maintained during positioning module is being connected to power. In the case of ROM setting, it is
maintained without the power connection of positioning module.
(b) The number of ROM setting operating is unlimited because basic parameter of positioning module is saved
on MRAM.
(c) Basic parameter setting command is unavailable to be executed when the axis is operating.