Chapter 8 Program
8-103
(2) Direct Start
(a) This is the condition for Direct Start
This is the condition for Direct Start Command (XPM_DST)
(b) Axis ready
If communication between the positioning module and the servo driver is normal, corresponding signal will
be on.
(c) Operating state by axis
According to exercise from “Chapter 8.2.2 Current State Reading,” it is a signal of “Operating” for each axis. It
turns on when it is operating. Direct Start command can not be configured while it is running hence
configuration will only be configured when it is not running. If you execute Direct Start while it is running, the
“error 221” would be appeared.
(d) Error state for each axis
According to exercise from “Chapter 8.2.2 Current State Reading,” it is a signal of “Error state” for each axis. It
turns on when an error occurred. Operation will only work when there is no er ror. If you want to operate a
system regardless of errors, you can just inactivate the function.
(a) Condition for direct start
(b) Axis ready state
(c) Operating state
(d) Error state
(e) Servo on signal
(f) Position of the module
(p) Completion state
(q) Error state
(g) Command axis
(h) Target position
(i) Target speed
(i) Dwell time
(k) M code
(l) Control method
(m) Coordinate setting
(n) Change acc. time
(o) Change dec. time