Chapter 6 Command
6-32
6.3.24 Return to the Position before Manual Operation (Command : XRTP)
(1) Program
(2) Descriptiodkn
Device
Description
M00017
axis1 return to the position before manual operation start
input
U02.00.0
axis1 ready
D00000.0
axis1 in operation
D00000.1
axis1 error state
D00003.9
axis1 servo on signal
D00003.A axis1 servo error
Comman
d
XRTP
Return to the position before manual
operation
Operand
OP1 Slot
Constant
WOR
D
Slot No. installed with positioning module
OP2 Axis PMLK,constant,D,Z,R,ZR
WOR
D
Command axis
XBF-PN04B: 1axis~4axis
XBF-PN08B:1axis~8axis
※
PMLK means P, M, L and K areas.
(a) If the current position is changed as external axis speed sync. operation, inching operation, Jog operation
after completing the positioning, it returns to the previous position of manual operation.
(b) Return to the position before manual operation command will be ignored if it is not in manual operation.
(c) The detail description about return to the previous position of manual operation, refer to “9.3.3 Return to the
Previous Position of Manual Operation”
(d) D device signal (axis1 in Operation, etc) which used in the example above is an assumption that saving the
axis state value in D device area with XSRD command.