7.11.6 Servo Error History Reset (XPM_SHRST)
Form of Function Block
Description
Input
REQ : Request for execution of function block
BASE : Set the base no. with module
SLOT : Set the slot no. with module
AXIS : Axis to command
XBF-PN04B:1~4, XBF-PN08B:1~8
Output
DONE : Maintain 1 after first operating
STAT : Output the error no. in operation
(1) Give “Servo Error Reset” command to the axis designated as the axis of positioning module with BASE (Base
no. of Positioning module) and SLOT (Slot no. of Positioning module).
(2) Give the command that clears servo driver alarm history occurred at the specific axis among servo drivers
connected to the positioning module.
(3) Servo drive can save up to 10 servo alarm history.
(4) You can set axis to command in “AXIS” and the following value is available. If you set other values, error code
“6” appears.
XBF-PN04B:1~4, XBF-PN08B:1~8
(5) servo error history reset is not supported.