Chapter 6 Command
6-33
6.3.25 Start Step No. Change (Command : XSNS)
(1) Program
(2) Description
Device
Description
M00018
axis1 start step No. change input
U02.00.0
axis1 ready
D00000.0
axis1 signal in operation
D00000.1
axis1 error state
D01300
axis1 start step no. to change
Comman
d
XSNS
Change start step No.
Operand
OP1
Slot
Constant
WORD Slot No. installed with positioning module
OP2
Axis
PMLK,constant,D,Z,R,ZR WORD
Command axis
XBF-PN04B: 1axis~4axis
XBF-PN08B:1axis~8axis
OP3 Step No. PMLK,constant,D,Z,R,ZR WORD step No. to change with start step
(1~400)
※
PMLK means P, M, L and K areas.
(a) Change the current step into the step value which set on step no.(OP3)
(b) It is not available to be executed in operation.
(c) D device signal (axis1 in Operation, etc) which used in the example above is an assumption that saving the
axis state value in D device area with XSRD command.