Chapter 9 Functions
9-174
The value that is saved to device address is as follows.
Device Number
Size
Contents
Device
WORD
The number of latch position data
1
WORD
-
2
DINT
The latch position data 1
4
DINT
The latch position data 2
6
DINT
The latch position data 3
8
DINT
The latch position data 4
10
DINT
The latch position data 5
12
DINT
The latch position data 6
14
DINT
The latch position data 7
16
DINT
The latch position data 8
18
DINT
The latch position data 9
20
DINT
The latch position data 10
(f) Motion timing(single trigger mode)
Position
Time
ON
Status of l atch
completion
Spe ed
3000
Time
Sign al of touch
prob e1
Reading address of latch data
The number of la tch positio n d ata = 2
Latch p osi tion da ta 1 = 300 0
Latch p osi tion da ta 2 = 105 00
:
:
Latch p osi tion da ta 10
10500
Start
comma nd
Comma nd of latch
reset(Reset latch
completion)
ON
Comma nd of latch
setting(Ena ble
latch)
1
2
ON
In single trigger mode, only the first touch probe 1 signal can do latch of current position after being
latch enable
You can use latch function by signal of touch probe 1 again with latch reset command that is executed
after operating the latch function by the first signal of touch probe 1.