Chapter 6 Command
6-68
6.3.42 Emergency Stop (Command : XEMG)
(1) Program
(2) Description
Device
Description
M00028 axis1 internal emergency stop input
U02.00.0 axis1 ready
Comman
d
XEMG
Emergency stop
Operand
OP1 Slot
Constant
WOR
D
Slot No. installed with positioning
module
OP2 Axis PMLK,constant,D,Z,R,ZR
WOR
D
Command axis
XBF-PN04B: 1axis~4axis
XBF-PN08B:1axis~8axis
※
PMLK means P, M, L and K areas.
(a) Execute internal emergency stop command to command axis.
(b) Dec. time in emergency stop become the time which set on “Emergency stop dec. time” item of each basic
parameter.
(c) The example program above is the command stop axis1 emergently.