Chapter 6 Command
6-11
Command
XSST
Linear interpolation
Operand
OP1
Slot
Constant
WOR
D
Slot No. installed with positioning
module
OP2
Axis
PMLK,constant,D,Z,R,ZR WOR
D
Command axis
XBF-PN04B: 1axis~4axis
XBF-PN08B:1axis~8axis
OP3
Operation
axis
PMLK,constant,D,Z,R,ZR WOR
D
Operating axis setting
※
PMLK means P, M, L and K areas.
(a) Simultaneous command is the command operates simultaneous steps saved in ‘operation axis(OP3)’ at a time.
(b) Axis setting is set by setting the bits to the axis
15 ~ 8 Bit
7Bit
6Bit
5Bit
4Bit
3Bit
2Bit
1Bit
0Bit
Not use
Axis
8
Axis
7
Axis
6
Axis
5
Axis
4
Axis
3
Axis
2
Axis
1
That is, axis5, axis2, axis1 will be set if set as h0013
But, the axis which command simultaneous start is basically included without being set in operating axis.
(c) In the example program above, axis1 operates step no.1, axis2 operates step no.5, axis5 operates step no.10.
(d) To set steps of axis for simultaneous start, use XSWR command or PUT/PUTP command to set simultaneous
start step no. on s imultaneous start step memory address. This must be complete before simultaneous start
executes.
(e) D device signal (axis1 in Operation, etc) which used in the example above is an assumption that saving the axis
state value in D device area with XSRD command.
Summary of Contents for XBF-PN04B
Page 1: ...Programmable Logic Controller Positioning Module EtherCAT XGB Series XBF PN04B XBF PN08B ...
Page 626: ...Chapter 9 Functions BPS37 setup RS232 and PC connection BPS37 option board LED 9 193 ...
Page 796: ...Appendix3 Dimension A3 1 Appendix 3 Dimension Appendix 3 1 Dimension of XBF PN04B PN08B ...