Chapter 8 Program
8-51
(3) Position Assign Speed Override
(a) Condition of Position Assign Speed Override
Condition of Position Assign Speed Override Command (XPSO)
(b) Axis ready status
If communication between positioning module and s ervo drive is done, the signal corresponding to each
signal will be on.
(c) Operating state by axis
According to exercise from “Chapter 8.1.2 Current State Reading,” it is a signal of “Operating” for each axis. It
turns on when it is operating. Operating Data Setting can not be configured while it is running hence
configuration will only be configured when it is not running. If you execute Position Assign Speed Override
while it is running, the “error 381” would be appeared.
(b) Axis ready state
(d) Error state
(c) Operation state
(e) Position of the module
(f) Command axis
(a) Condition for position assign speed
override
(g) Position to change speed
(h) Operation speed value to change
Changes speed into D01200
when position of 1-axis is
D01100
Changes speed into D01202
when position of 2-axis is
D01102
Changes speed into D01204
when position of 3-axis is
D01104
Changes speed into D01206
when position of 4-axis is
D01106
Changes speed into 10000
when position of 5-axis is
D01108
Changes speed into D01210
when position of 6-axis is
D01110
Changes speed into 5000
when position of 7-axis is
100000
Changes speed into 100000
when position of 8-axis is
5000