Chapter 9 Functions
9-120
[Example] axis1 is main axis, axis2 is sub axis. Operate at “ratio of main axis : ratio of sub axis = 2 : 1”
at the beginning and then execute sp
eed sync. control changing the ratio to “ratio of main axis :
ratio of sub axis = 1 : 2”
■ Example of setting in XG-PM
▪Operation data of main axis(axis1)
Step no.
Control method
Operation
method
Goal Position
[pls]
Operating speed
[pls/s]
Acc. no.
Dec. no.
M code
Dwell
Time
1
Incremental,
Reduction position
control
Single,
End
10000
2000
No. 1
No. 1
0
0
■ Operating pattern
Time
Speed
Main axis
Start command
Main axis
in operation
Main axis
positioning
complete signal
ON
ON
2000
Sub axis
Speed sync.
command
ON
Sub axis
In operation
ON
Ratio of main axis : 2
Sub axis stop
command
ON
Stop but
not turn On
Sub axis
positioning
complete signal
ON
ON
1000
4000
Ratio of sub axis : 1
Ratio of main axis : 1
Ratio of sub axis : 2