Chapter 8 Program
8-142
(4) Servo Driver Error History Reset
(a) This is the condition for Servo Driver Error History Reset
This is the condition for Servo Driver Error History Reset Command (XPM_SHRST). Once Servo Driver Error
Reset is executed, it erases history of generated errors of servo driver. Servo driver can have ten error
histories by each axis.
(b) Axis ready
If communication between the positioning module and the servo driver is normal, corresponding signal will be
on.
(c) Address of Positioning Module
In this example, Positioning Module is installed at the 3 slot of 0 bases.
(d) Axis of command execution
You can set an axis for Parameter Setting. XBF-PN04(8)B supports for 4(8) axes. In the “execution of axis”
from the configuration of Parameter Setting, you can set a value for axis1 through axis 4(8).
(e) State of Operation complete
If function block is completed without error, “1” will be outputted and m aintain “1” until the next operation. If
error occurred, “0” will be outputted.
(f) Error State
This is the area that output error no. if there are errors in operation of function block.
(b) Axis ready state
(a) Condition for Servo driver error history reset
(d) Command axis
(c) Position of the module
(e) Completion state
(f) Error state