Chapter 8 Program
8-44
(e) Address of Positioning Module
In this example, Positioning Module installed at the slot no.3 of 0 bases.
(f) Axis of command execution
You can set an axis for Deceleration Stop. XBF-PN04(8)B can supports for 4(8) axes. In the “execution of axis”
from the configuration of Deceleration Stop, you can set a value for axis 1 through 4(8) axis.
(g) Deceleration time of Deceleration Stop
Setting a deceleration time of Deceleration Stop operation. Unit of Deceleration Stop is [ms]. Since this time
refers deceleration time from the speed limit, there might be little difference between Deceleration Stop set
time and actual stop time. The range of deceleration time is “0~2,147,483,674.” 1~2,147,483,674 means
Deceleration Time set as 1ms ~ 2,147483674ms. If it set as “0,” it will be operated with set deceleration value.
Also it use to stop Speed Synchronous Operation or CAM Operation while Speed and CAM Operation. During
this time Deceleration Time is meaningless, CAM Operation Is just cancelled.
(i) For more information, reference of Deceleration Stop is in the “Chapter 9.2.18.”
(12) Emergency Stop
(b) Axis ready state
(a) Condition for EMC. stop
(c) Position of the module
(d) Command axis
8-axis EMG. stop
7-axis EMG. stop
6-axis EMG. stop
5-axis EMG. stop
4-axis EMG. stop
3-axis EMG. stop
2-axis EMG. stop
1-axis EMG. stop