Chapter 4 Positioning Parameter & Operation Data
4-19
(12) Positioning Completion Condition
(a) Positioning Completion signal notify that operation has been completed without stop factor
(b) There are 4 kinds of methods for positioning completion condition.
1) by dwell time
2) by in-position signal
3) by using both dwell time and in-position signal
4) by using either dwell time or in-position signal.
(c) Though target reaches goal position and pos itioning is complete, “in operation” status is kept until
positioning completion condition is met. If positioning completion condition is met, “in operation” signal
will be off and it goes to “Positioning completion” status.
(d) The following is timing diagram for each method.
1) Method by dwell time
If it reaches goal and stops, positioning complete signal will be on after Dwell time
Speed
Start
In operation
Dwell time
Time
Positioning
completion
Command
speed
Current
Speed
During dwell