Chapter 6 Command
6-77
6.3.49 Disconnect Servo (Command: XDCON)
(1) Program
(2) Description
Device
Description
M0035
Servo disconnection input
Comman
d
XDCON
Servo Disconnection
Operand
OP1 Slot
Constant
WOR
D
Slot No. installed with positioning module
OP2 Axis
PMLK,constant,D,Z,R,ZR
WOR
D
Command axis
XBF-PN04B: 1axis~4axis
XBF-PN08B:1axis~8axis
※
PMLK means P, M, L and K areas.
(a) This is the command that disconnects the communication between the positioning module and the servo
driver connected to that module through Ethernet cable.
(b) If servo drive is disconnected normally, a bi t corresponding to the connected axis of U device will be
cleared.
Axis
Signal direction: PLC CPU
P o s itio n in g
module
Input
signal
Contents
1-axis
Uxx.00.0
1-axis ready
2-axis
Uxx.00.1
2-axis ready
3-axis
Uxx.00.2
3-axis ready
4-axis
Uxx.00.3
4-axis ready
5-axis
Uxx.00.4
5-axis ready
6-axis
Uxx.00.5
6-axis ready
7-axis
Uxx.00.6
7-axis ready
8-axis
Uxx.00.7
8-axis ready
(c) Don’t give the command to each axis and give the command to the one axis among 1-axis~8-axis