Chapter 9 Functions
9-102
(4) Stop hardware by high/low limit
(a) When positioning control, if the signal of hardware high/low limit is inputted, then stop positioning control and
it will be decelerated and stopped as set time at
「
deceleration time when it is suddenly stopped
」
, and error
will be occurred.
(b) In case of external input stroke high limit error, error 492 will occur and in case of external input stroke low limit
error, error 493 will occur.
■ Setting related parameter (basic parameter)
Item
Setting value
Content
When sudden
stop, deceleration
time
0 ~ 2147483647 [ms]
Set deceleration time for using when detect hardware
high/low limit signal. Deceleration time express needed
time for deceleration as bias speed at speed limit, when
suddenly stop.
(c) Motion timing
Time
Seed
Start command
Operating
Input external
stroke high/low limit
ON
ON
ON
Signal of complete
positioning
Setting speed
Decelerate and stop
as deceleration time
when sudden stop
Summary of Contents for XBF-PN04B