Chapter 6 Command
6-73
(d) Point start step data will be set like item below depending on the leading no. of device.
No.
Device No.
POINT start step data
1
0
POINT start step data 1
2
1
POINT start step data 2
3
2
POINT start step data 3
4
3
POINT start step data 4
5
4
POINT start step data 5
6
5
POINT start step data 6
7
6
POINT start step data 7
8
7
POINT start step data 8
9
8
POINT start step data 9
10
9
POINT start step data 10
11
10
POINT start step data 11
12
11
POINT start step data 12
13
12
POINT start step data 13
14
13
POINT start step data 14
15
14
POINT start step data 15
16
15
POINT start step data 16
17
16
POINT start step data 17
18
17
POINT start step data 18
19
18
POINT start step data 19
20
19
POINT start step data 20
(e) Step data must be set in point start data area before execute point start.
(f) For detail description of point start operation, refer to “9.2.18 Positioning Start (4) Point Start”.
(g) The example program above sets 10 point steps from D03000 on axis1 and executes point start to 5 point
steps which already set.
(h) It is possible to set point operation step with PUT command. At that time, refer to memory address of “5.1.1
Point Operation Step Data” and “6.1.2 Internal Memory Writing”. If apply PUT to the example program above,
refer to follows.