349
Read and complete the steps in
Sections 11.03.
The manual calibration for the camera needs to be
completed before attempting to do automatic PNC applications.
Record your camera calibration settings! It is very common for those settings to resort to defaults during
software updates and if you use other cutters with SCAL.
Make sure you have updated SCAL to version 4.068 or later.
Make sure you have updated C3 to version 0.5.57 or later.
(1) Due to a current bug, you need to change the Camera offset values in C3 before using Auto PNC in SCAL.
Open C3 and click on the
Settings
tab. In the
Basic settings
window, change the
Units
to
Inches
. Then
click on
Apply Changes
:
(2) Click on
Machine settings
and please record your current camera offsets in case an update to the bug
issue is resolved. Then change the
X offset for electronic eye
to 0.837 and
Y offset for electronic eye
to
0.224 as shown below, even though these are not your camera offsets. Then click on
Apply changes
.
(3) In SCAL, to switch back and forth between Manual and Auto PNC, change the
Mark type
under
Cutter>Cutter Settings
. Then click on
Save.