• QUADEN = 0
• DECAPEN = 0
• COMP = 1
In Complementary mode, the channel (n+1) output is the inverse of the channel (n)
output.
So, the channel (n+1) output is the same as the channel (n) output when:
• QUADEN = 0
• DECAPEN = 0
• COMP = 0
FTM counter
channel (n+1) match
channel (n+1) output
with COMP = 1
channel (n+1) output
with COMP = 0
channel (n) output
with ELSnB:ELSnA = 1:0
channel (n) match
Figure 38-204. Channel (n+1) output in Complementary mode with (ELSnB:ELSnA = 1:0)
FTM counter
channel (n+1) match
channel (n+1) output
with COMP = 1
channel (n+1) output
with COMP = 0
channel (n) output
with ELSnB:ELSnA = X:1
channel (n) match
Figure 38-205. Channel (n+1) output in Complementary mode with (ELSnB:ELSnA = X:1)
NOTE
The complementary mode is not available in Output Compare
mode.
38.4.10 Registers updated from write buffers
Chapter 38 FlexTimer Module (FTM)
K22F Sub-Family Reference Manual , Rev. 3, 7/2014
Freescale Semiconductor, Inc.
893