25.1.2 Modes of Operation
The MCG has the following modes of operation: FEI, FEE, FBI, FBE, PBE, PEE, BLPI,
BLPE, and Stop. For details, see
.
25.2 External Signal Description
There are no MCG signals that connect off chip.
25.3 Memory Map/Register Definition
This section includes the memory map and register definition.
The MCG registers can only be written when in supervisor mode. Write accesses when in
user mode will result in a bus error. Read accesses may be performed in both supervisor
and user mode.
MCG memory map
Absolute
address
(hex)
Register name
Width
(in bits)
Access Reset value
Section/
page
4006_4000 MCG Control 1 Register (MCG_C1)
8
R/W
04h
4006_4001 MCG Control 2 Register (MCG_C2)
8
R/W
80h
4006_4002 MCG Control 3 Register (MCG_C3)
8
R/W
Undefined
4006_4003 MCG Control 4 Register (MCG_C4)
8
R/W
Undefined
4006_4004 MCG Control 5 Register (MCG_C5)
8
R/W
00h
4006_4005 MCG Control 6 Register (MCG_C6)
8
R/W
00h
4006_4006 MCG Status Register (MCG_S)
8
R
10h
4006_4008 MCG Status and Control Register (MCG_SC)
8
R/W
02h
4006_400A
MCG Auto Trim Compare Value High Register
(MCG_ATCVH)
8
R/W
00h
4006_400B
MCG Auto Trim Compare Value Low Register
(MCG_ATCVL)
8
R/W
00h
4006_400C MCG Control 7 Register (MCG_C7)
8
R/W
00h
4006_400D MCG Control 8 Register (MCG_C8)
8
R/W
80h
Chapter 25 Multipurpose Clock Generator (MCG)
K22F Sub-Family Reference Manual , Rev. 3, 7/2014
Freescale Semiconductor, Inc.
535