Error solving manual.
CNC 8060
CNC 8065
·150·
(R
EF
: 1709)
5000-5999
5000
'PLC error: The timer does not exist'
DETECTION
PLC timer data reading processes.
CAUSE
Request to read a timer that does not exist.
SOLUTION
Check the number of the timer; valid timers, T1 to T256.
5001
'PLC error: The counter does not exist'
DETECTION
PLC counter data reading processes.
CAUSE
Request to read a counter that does not exist.
SOLUTION
Check the number of the counter; valid counters, T1 to T256.
5002
'CNCRD: Unidentified variable'
DETECTION
When executing a CNCRD instruction.
CAUSE
The variable does not exist. If the error occurs during start-up, the PLC may be trying
to execute a CNCRD instruction before the SERCOSRDY mark is active.
SOLUTION
Check the syntax of the variable. If the error occurs during start-up, condition the
reading of the variable to the PLC mark SERCOSRDY being active.
5003
'CNCWR: Unidentified variable'
DETECTION
When executing a CNCWR instruction.
CAUSE
The variable does not exist.
SOLUTION
Check the syntax of the variable.
5004
'Variable without reading permission for PLC'
DETECTION
When executing a CNCRD instruction.
CAUSE
Reading of a variable that has no reading permission for the PLC.
SOLUTION
Check the permissions of the variable.
5005
'Variable without writing permission for PLC'
DETECTION
When executing a CNCWR instruction.
CAUSE
Writing of a variable that has no writing permission for the PLC.
SOLUTION
Check the permissions of the variable.
5006
'Variable writing from the PLC out of range'
DETECTION
When executing a CNCWR instruction.
CAUSE
The value assigned to the variable is not valid.
SOLUTION
Check the syntax of the variable and the valid values.
5007
'Syntax error when writing the variable from the PLC'
DETECTION
When executing a CNCWR instruction.
CAUSE
The variable does not exist or it has no permission to be written from the PLC.
SOLUTION
Check the syntax and the permissions of the variable.
5008
'The variable could not be written from the PLC'
DETECTION
When executing a CNCWR instruction.
CAUSE
Writing a global or local arithmetic parameter that does not exist.
SOLUTION
Check the settings of global and local parameters as well as the PLC program.
5009
'Syntax error when reading the variable from the PLC'
DETECTION
When executing a CNCRD instruction.
CAUSE
The variable does not exist or it has no permission to be read from the PLC.
SOLUTION
Check the syntax and the permissions of the variable.
Summary of Contents for 8065
Page 1: ...Ref 1709 8060 8065 CNC Error solving manual...
Page 4: ...BLANK PAGE 4...
Page 216: ...Error solving manual CNC 8060 CNC 8065 216 REF 1709...
Page 217: ...Error solving manual CNC 8060 CNC 8065 217 User notes REF 1709...
Page 218: ...Error solving manual CNC 8060 CNC 8065 218 User notes REF 1709...
Page 219: ...Error solving manual CNC 8060 CNC 8065 219 User notes REF 1709...