0044
'Wrong axis name or undefined axis name'
DETECTION
During the validation of the machine parameters.
CAUSE
The machine parameter is not defined or it has the wrong axis name.
SOLUTION
Correct the machine parameters. The valid axis names are the ones defined in
parameter AXISNAME.
In parameter AXISNAME, the axis name must be defined by 1 or 2 characters. The
first character must be one of the letters X - Y - Z - U - V - W - A - B - C. The second
character is optional and will be a numerical suffix between 1 and 9. This way, the
name of the spindles may be within the range X, X1…X9,...C, C1…C9.
0045
'Wrong spindle name'
DETECTION
During the validation of the machine parameters.
CAUSE
The user has defined the machine parameter with the wrong spindle name.
SOLUTION
Correct the machine parameters. The valid spindle names are the ones defined in
parameter SPDLNAME.
In parameter SPDLNAME, the spindle name must be defined by 1 or 2 characters.
The first character must be the letter S. The second character is optional and will be
a numerical suffix between 1 and 9. This way, the name of the spindles may be within
the range S, S1 ... S9.
0046
'Nonexistent axis'
DETECTION
During the validation of the machine parameters.
CAUSE
The possible causes are:
• The user has assigned the name of an axis that does not exist to a machine
parameter.
• Either the VMOVAXIS or VCOMPAXIS axis is undefined in the basic volumetric
compensation.
SOLUTION
Correct the machine parameters. The valid axis names are the ones defined in
parameter AXISNAME.
0047
'A main axis cannot be defined as slave'
DETECTION
During the validation of the machine parameters.
CAUSE
The slave axis of a gantry axis is the master of another gantry axis.
SOLUTION
Correct the gantry axes table. The master axis of a gantry axis cannot be the slave
of another gantry axis.
0048
'An axis cannot be a slave of several masters'
DETECTION
During the validation of the machine parameters.
CAUSE
The slave axis of a gantry axis is already defined as the slave axis in another gantry
axis.
SOLUTION
Correct the gantry axes table. An axis cannot be the slave of several masters.
0049
'A master axis cannot be a slave and vice versa'
DETECTION
During the validation of the machine parameters.
CAUSE
The master axis of a gantry axis is the slave of another gantry axis or vice versa.
SOLUTION
Correct the gantry axes table. The master axis of a gantry axis cannot be the slave
of another gantry axis or vice versa.
0050
'The master and slave axes must be of the same type (AXISTYPE)'
DETECTION
During the validation of the machine parameters.
CAUSE
Both axes of a gantry pair are not of the same type; linear or rotary.
SOLUTION
The axes of a gantry pair must be of the same type, linear or rotary (parameter
AXISTYPE). Check the gantry axes table and/or the AXISTYPE parameter of both
axes.
0051
'The master and slave axes must have certain parameters with the same value'
DETECTION
During the validation of the machine parameters.
CAUSE
The two axes of a gantry axis do not have the same properties.
SOLUTION
Check the gantry axes table and/or the following machine parameters of the axes.
• The linear axes must have parameters AXISMODE, FACEAXIS and LONGAXIS
set the same way.
• The rotary axes must have parameters AXISMODE, SHORTESTWAY and
CAXIS set the same way.
Summary of Contents for 8065
Page 1: ...Ref 1709 8060 8065 CNC Error solving manual...
Page 4: ...BLANK PAGE 4...
Page 216: ...Error solving manual CNC 8060 CNC 8065 216 REF 1709...
Page 217: ...Error solving manual CNC 8060 CNC 8065 217 User notes REF 1709...
Page 218: ...Error solving manual CNC 8060 CNC 8065 218 User notes REF 1709...
Page 219: ...Error solving manual CNC 8060 CNC 8065 219 User notes REF 1709...