Error solving manual.
CNC 8060
CNC 8065
·162·
(R
EF
: 1709)
6055
'Failure when reading local handwheels periodically'
DETECTION
During the execution of the CNC.
CAUSE
Failure when reading local handwheels cyclically.
SOLUTION
Check the connection and the voltage supply for the local handwheels.
6056
'Short-circuit at the jog handwheel (over-current alarm)'
DETECTION
During the execution of the CNC.
CAUSE
Over-current alarm at the handwheel connected to the local jog.
SOLUTION
Check the connection and the voltage supply for the local handwheels.
6057
'Handwheel feedback alarm'
DETECTION
During the execution of the CNC.
CAUSE
Feedback alarm at the handwheel connected to the local feedback
SOLUTION
Check the connection and the voltage supply for the local handwheels.
6058
'Some CANopen node is not in the operational phase'
DETECTION
After a CNC reset.
CAUSE
When reinitializing the CANopen during a CNC reset, some node has not reached
the operational phase.
SOLUTION
Check the connection and configuration of the CANopen nodes.
6059
Error in the configuration of the analog input.
DETECTION
During CNC power-up or after a reset.
CAUSE
During the initialization of the CANopen bus, it was not possible to correctly configure
any of the parameterized current inputs.
SOLUTION
Check the parameterization of the analog current inputs.
6060
Error in the configuration of the analog output.
DETECTION
During CNC power-up or after a reset.
CAUSE
During the initialization of the CANopen bus, it was not possible to correctly configure
any of the parameterized current outputs.
SOLUTION
Check the parameterization of the analog current outputs.
6061
Non-Fagor CANopen nodes. Software option not allowed.
DETECTION
During the initialization of the CANopen bus, while the CNC was starting-up or after
a reset.
CAUSE
During the initialization of the CANopen bus, third party nodes had been detected
without the corresponding software option.
SOLUTION
Disconnect any non-Fagor nodes from the CANopen bus or purchase the software
option so that it may be used.
6062
Emergency relay open due to a bus reinitialization error.
DETECTION
Following a CNC reset or during machine parameter validation.
CAUSE
During machine parameter reset or validation, it was not possible to successfully
complete the execution of the process due to an error arising after the reassembly
of the CAN bus or the Sercos ring. As a result, the emergency relay has been left open.
VALUE 1
Sercos error during a CNC reset process.
VALUE 2
CAN error during a CNC reset process.
VALUE 3
Sercos and CAN error during a CNC reset process.
VALUE 4
Sercos error during a CNC validation process for the machine parameters.
VALUE 8
CAN error during a CNC validation process for the machine parameters.
VALUE 12
Sercos and CAN error during a CNC validation process for the machine parameters.
SOLUTION
Correct the CAN or Sercos issue preventing the emergency relay from closing.
Summary of Contents for 8065
Page 1: ...Ref 1709 8060 8065 CNC Error solving manual...
Page 4: ...BLANK PAGE 4...
Page 216: ...Error solving manual CNC 8060 CNC 8065 216 REF 1709...
Page 217: ...Error solving manual CNC 8060 CNC 8065 217 User notes REF 1709...
Page 218: ...Error solving manual CNC 8060 CNC 8065 218 User notes REF 1709...
Page 219: ...Error solving manual CNC 8060 CNC 8065 219 User notes REF 1709...