Error solving manual.
CNC 8060
CNC 8065
·145·
(R
EF
: 1709)
4018
Remote Sercos feedback with incoherent FEEDBACKTYPE in various gears (ranges).
DETECTION
When initializing the Sercos bus; CNC start-up, validation of machine parameters and
reset.
CAUSE
If there is any feedback input for the RCS-S module, the feedback (parameter
FEEDBACKTYPE) is not the same for all sets.
SOLUTION
Correct the parameterization.
4019
Sercos ring error due to a counter reset.
DETECTION
When initializing the Sercos bus; CNC start-up, validation of machine parameters and
reset.
CAUSE
A reset has occurred for the RCS-S module, due to either a physical cause (power
outage, etc.) or internally because of the node software.
SOLUTION
Remedy the cause of the problem. If the error persists, contact Fagor.
4020
Incoherent parameter settings.
DETECTION
When initializing the Sercos bus; CNC start-up, validation of machine parameters and
reset.
CAUSE
Incorrect parameterization of the RCS-S module or its resources.
SOLUTION
Correct the parameterization.
4022
Sercos ring error due to a counter reset by Watchdog.
DETECTION
When initializing the Sercos bus; CNC start-up, validation of machine parameters and
reset.
CAUSE
A watchdog reset has occurred for the RCS-S module, due to an internal cause
regarding the node software.
SOLUTION
Contact Fagor.
4023
The trace configured in Sercos cannot be configured.
DETECTION
When initializing the Sercos bus; CNC start-up, validation of machine parameters and
reset.
CAUSE
Error during the configuration of the AT-MDT telegrams to capture the programmed
trace. The programmed trace cannot be realized, either because it is a non-Fagor
drive or because there is no space available for it.
SOLUTION
Reduce the number of variables in the telegram. If the bandwidth is limited, raise the
SERBRATE frequency or remove drives from the ring.
4024
Invalid drive version for in-position TANDEM axis or for REFMODE CNC.
DETECTION
When initializing the Sercos bus; CNC start-up, validation of machine parameters and
reset.
CAUSE
The version of a drive does not support tandem torque control or CNC reference
mode.
SOLUTION
To install the above features, install a version later than v6.28 or v8.08 on the drives.
4025
A Multi-Axis Box (MAB) has not been identified on the Sercos ring.
DETECTION
When initializing the Sercos bus; CNC start-up, validation of machine parameters and
reset.
CAUSE
A MAB has not been detected in the system. A MAB is required for the option
MABSYSTEM when there is more than one drive on the Sercos ring.
SOLUTION
Delete the MABSYSTEM option or include a MAB in the Sercos configuration.
4026
Inconsistent FeeDat/EnDat encoder data. A new configuration must be validated.
DETECTION
When initializing the Sercos bus; CNC start-up, validation of machine parameters and
reset.
CAUSE
There is one or more FeeDat/EnDat feedback, where the data being read from the
encoder is different from those stored on disk. The encoder of the feedback,
therefore, is different from the one that was validated during the system setup.
SOLUTION
The encoder that was validated for each FeeDat/EnDat feedback must be
reconnected or the new encoder must be connected.
Summary of Contents for 8065
Page 1: ...Ref 1709 8060 8065 CNC Error solving manual...
Page 4: ...BLANK PAGE 4...
Page 216: ...Error solving manual CNC 8060 CNC 8065 216 REF 1709...
Page 217: ...Error solving manual CNC 8060 CNC 8065 217 User notes REF 1709...
Page 218: ...Error solving manual CNC 8060 CNC 8065 218 User notes REF 1709...
Page 219: ...Error solving manual CNC 8060 CNC 8065 219 User notes REF 1709...