Error solving manual.
CNC 8060
CNC 8065
·147·
(R
EF
: 1709)
4206
'SERCOS drive error'
AXIS
Logic number of the axis
CAUSE
The drive reports an error.
SOLUTION
Analyze error codes. Refer to the drive manual.
4207
'Drive Status Ready (DRSTAF/DRSTAS) is missing'
DETECTION
During execution.
CAUSE
Monitoring of DRSTAF, DRSTAS or of the tandem, when the axis is moving.
SOLUTION
Check the enable signals and the status of the drive.
4209
’Error in the SERCOS ring (optical fiber)'
VALUE
Error codes that identify the source or sources of the problem.
CAUSE
Broken Sercos ring causing a loss of Phase 4.
SOLUTION
Check the following:
• Verify that the optical fiber is properly connected and in good condition.
• Check the parameter settings at the CNC and at the drives. Node selector of the
drive (DriveID), parameters LOOPTIME, SERPOWSE, SERBRATE, OPMODE,
etc.
4210
’Error in the SERCOS ring (MST lost)'
VALUE
Error codes that identify the source or sources of the problem.
CAUSE
A synchronism message got lost causing the loss of phase 4.
SOLUTION
Ensure connectivity through the whole ring (optical fiber, master and slaves).
4211
’Error in the SERCOS ring (2 AT's lost)'
AXIS
Logic number of the axis
VALUE
Error codes that identify the source or sources of the problem.
CAUSE
Some drive has lost responses causing the loss of phase 4.
SOLUTION
Determine the defective drive and replace the Sercos board or the drive itself. Contact
our technical service department.
4212
’Error in the Sercos ring (AT reception)'
AXIS
Logic number of the axis
VALUE
Error codes that identify the source or sources of the problem.
CAUSE
Error at the Sercos bus that causes a loss of Phase 4.
SOLUTION
Ensure connectivity through the whole ring (optical fiber, master and slaves).
4213
'SERCOS counter error'
NODE
Sercos ID of counter node.
CODE
Error code of the module. See
"RCS-S module."
on page 208.
CAUSE
The counter reports an error.
SOLUTION
Analyze error codes (See counter manual).
Code.
Meaning.
0x00000002
Broken optical fiber.
Code.
Meaning.
0x00000200
MST loss.
Code.
Meaning.
0x00000100
AT loss.
Code.
Meaning.
0x00008000
AT transmission error. (Optic fiber or drive reset)
Summary of Contents for 8065
Page 1: ...Ref 1709 8060 8065 CNC Error solving manual...
Page 4: ...BLANK PAGE 4...
Page 216: ...Error solving manual CNC 8060 CNC 8065 216 REF 1709...
Page 217: ...Error solving manual CNC 8060 CNC 8065 217 User notes REF 1709...
Page 218: ...Error solving manual CNC 8060 CNC 8065 218 User notes REF 1709...
Page 219: ...Error solving manual CNC 8060 CNC 8065 219 User notes REF 1709...