4214
'Error while searching home on the Sercos counter'
NODE
Sercos ID of counter node.
VALUE 1
Sercos drive error Codes:
VALUE 2
Sercos drive error Codes:
VALUE 3
Status of the command that caused the error.
VALUE 4
IDN of the command that caused the error.
CAUSE
Error while homing an axis with remote Sercos feedback.
SOLUTION
Analize the parameter settings of the process; parameter REFPULSE in particular.
4300
'No Sercos variable server has been registered'
DETECTION
At the oscilloscope.
CAUSE
There is a Sercos variable defined in a channel of the oscilloscope, but there is no
server of Sercos variables to respond to the request.
SOLUTION
Verify that the CNC powered up correctly.
4301
Sercos variables cannot be accessed.
DETECTION
From the interface.
CAUSE
A Sercos drive variable has been requested by the interface, however, the variable
server has not been initialized correctly and it cannot access information on the
Sercos variables.
SOLUTION
Verify that the CNC powered up correctly.
4302
Unidentified Sercos variable.
DETECTION
From the interface.
CAUSE
A Sercos drive variable has been requested by the interface, however, the variable
is unknown.
SOLUTION
Check that the name of the Sercos variable is correct.
4303
'The Sercos variable has no sets"
DETECTION
At the oscilloscope.
CAUSE
There is a Sercos variable defined in a channel of the oscilloscope, whose syntax
indicates the set, but the variable has no sets.
SOLUTION
Eliminate the set indicator from the name of the variable.
4500
'Error when initializing the Mechatrolink Hw'
DETECTION
During CNC startup.
CAUSE
The Mechatrolink communication initialization stage could not be completed
successfully.
SOLUTION
Verify the setting of parameters for Mechatrolink communication (protocol, data size,
number of axes, etc.) have been set properly and the physical condition of the bus
(cables, terminating resistors, numbering of each station, etc.).
4501
'Mechatrolink command error'
DETECTION
During the execution of the CNC.
CAUSE
Failed execution of a Mechatrolink command from the master to a particular slave.
SOLUTION
Identify the command that has caused the error and the related slave. Analyze the
conditions, if any, so the command can be completed successfully (drive status,
voltage supply, power, motor connection, etc.).
4502
'Timeout when initializing the Mechatrolink'
DETECTION
During CNC startup.
CAUSE
The initialization of the Mechatrolink communication has not been completed.
SOLUTION
Verify the setting of parameters for Mechatrolink communication (protocol, data size,
number of axes, etc.) have been set properly and the physical condition of the bus
(cables, terminating resistors, numbering of each station, etc.).
4503
'Mechatrolink command alarm'
DETECTION
During the execution of the CNC.
CAUSE
The execution of a Mechatrolink command from the master to a particular slave
causes an alarm situation in that device.
SOLUTION
Identify the reported alarm code and see the manual of the Mechatrolink slave for
more detailed information.
Summary of Contents for 8065
Page 1: ...Ref 1709 8060 8065 CNC Error solving manual...
Page 4: ...BLANK PAGE 4...
Page 216: ...Error solving manual CNC 8060 CNC 8065 216 REF 1709...
Page 217: ...Error solving manual CNC 8060 CNC 8065 217 User notes REF 1709...
Page 218: ...Error solving manual CNC 8060 CNC 8065 218 User notes REF 1709...
Page 219: ...Error solving manual CNC 8060 CNC 8065 219 User notes REF 1709...