Error solving manual.
CNC 8060
CNC 8065
·202·
(R
EF
: 1709)
9000-9999
9301
'The REFFEED1 and REFFEED2 values of the master and slave axes must be the same'
DETECTION
During the validation of the machine parameters.
CAUSE
There is a gantry or tandem pair whose master and slave axes have different homing
feedrates in a set (parameters REFFEED1 and REFFEED2).
SOLUTION
Check the machine parameters. The fast and slow home search speeds (parameters
REFFEED1 and REFFEED2) must be the same for both axes.
9302
'Restart Windows to assume the new value'
DETECTION
During the validation of the machine parameters.
CAUSE
Some change in the machine parameters requires restarting Windows to be effective.
SOLUTION
Restart Windows.
9303
'The probe must be associated with a Fagor digital node input.
DETECTION
During the validation of the machine parameters.
CAUSE
Parameter PRBDI1 or PRBDI2 refers to an invalid digital input. Only the digital inputs
that belong to Fagor modules or the logic inputs used only to simulate the probe are
valid.
SOLUTION
Assign a digital input of a Fagor module or a logic input to parameters PRBDI1 and
PRBDI2.
9304
'Gantry axes: Both SERCOS axes must have the same OPMODEP'
DETECTION
During the validation of the machine parameters.
CAUSE
There is a gantry o tandem pair whose master and slave axes have parameter
OPMODEP set differently.
SOLUTION
Check the machine parameters. Both axes must have the OPMODEP parameter set
the same way.
9305
'It is recommended to decrease the filter order'
DETECTION
During the validation of the machine parameters.
CAUSE
The order number of one of the low passing filters of the axis is too high for the defined
frequency and it could cause overshooting.
SOLUTION
Check the machine parameters. Decrease the filter order or increase the frequency.
9306
'FAST filter incompatible with 3rd axis-filter'
DETECTION
During the validation of the machine parameters.
CAUSE
The CNC cannot activate the automatic filter of the HSC FAST because there are
already three frequency filters active on the axis.
SOLUTION
Remove a frequency filter of the axis or remove the filter of the HSC FAST mode.
9307
'With Motion Control software option, "CHTYPE" must be a PLC type channel'
DETECTION
During the validation of the machine parameters.
CAUSE
It is an MC model and some channel is not defined as PLC channel.
SOLUTION
Check the machine parameters. At the MC model, all the channels must be PLC
channels (parameter CHTYPE).
9308
'Compensation positions out of the module range are not allowed'
DETECTION
During the validation of the machine parameters.
CAUSE
The leadscrew or cross compensation table of the axis has positions that are defined
beyond the limits of the module.
SOLUTION
Define all the positions within the module limits.
Summary of Contents for 8065
Page 1: ...Ref 1709 8060 8065 CNC Error solving manual...
Page 4: ...BLANK PAGE 4...
Page 216: ...Error solving manual CNC 8060 CNC 8065 216 REF 1709...
Page 217: ...Error solving manual CNC 8060 CNC 8065 217 User notes REF 1709...
Page 218: ...Error solving manual CNC 8060 CNC 8065 218 User notes REF 1709...
Page 219: ...Error solving manual CNC 8060 CNC 8065 219 User notes REF 1709...