Error solving manual.
CNC 8060
CNC 8065
·169·
(R
EF
: 1709)
8020
The plc cannot be generated: Axis in motion or synchronized'
DETECTION
When trying to compile the PLC.
CAUSE
The PLC cannot be compiled while an axis is moving or synchronized.
SOLUTION
Stop the movement of the axes or de-synchronize the axis.
8021
'The plc cannot be generated: Spindle running'
DETECTION
When trying to compile the PLC.
CAUSE
The PLC cannot be compiled while a spindle is running.
SOLUTION
Stop the spindle.
8022
'The plc cannot be generated: Spindle synchronized'
DETECTION
When trying to compile the PLC.
CAUSE
The PLC cannot be compiled while a spindle is synchronized.
SOLUTION
De-synchronize the spindle.
8023
'Disk memory below recommended minimum'
DETECTION
During system startup.
CAUSE
The CNC has detected less than 50 MB of free disk memory.
SOLUTION
Check if there is a third-party application running and consuming system resources;
if so, close it. Turn the CNC off and back on. If the error persists, contact the Service
Department.
8024
'CNC running in setup mode'
DETECTION
On system startup, in setup mode.
CAUSE
The CNC has started up in setup mode and is working with unprotected disk.
SOLUTION
If you are not going to do the CNC setup, turn it off and use the DiskMonitor utility
to switch to user mode and work with the disk protected. Start the CNC up again.
8025
'A date change has been detected and it had to be restored'
DETECTION
During execution.
CAUSE
The CNC has detected a time and date change and it has restored them to their
expected values.
SOLUTION
Check whether the time and date are correct. If the error persists, contact the Service
Department.
8026
'OEM protection activated: The changes will be temporary'
DETECTION
While editing programs, PLC program or machine parameters.
CAUSE
The CNC is in user mode, with the OEM protection activated, and therefore all
changes will be temporary and will be lost when shutting the CNC down.
SOLUTION
Turn the CNC off and use the DiskMonitor utility to switch to setup mode. Start the
CNC up again.
8027
'Error when starting up the Kernel'
DETECTION
During system startup.
CAUSE
The kernel has been started up but is not activated.
SOLUTION
Verify that the CNC has started up correctly. Turn the CNC off and back on. If the error
persists, contact the Service Department.
8028
'Compiler not available'
DETECTION
During system startup.
CAUSE
The CNC has not found the folder where the PLC compiler has been installed.
SOLUTION
Contact our technical service department.
8029
'PLC "includes" not available'
DETECTION
During system startup.
CAUSE
The CNC has not found the folder where the includes needed to compile the PLC have
been installed.
SOLUTION
Contact our technical service department.
8030
'PLC libraries not available'
DETECTION
During system startup.
CAUSE
The CNC has not found the folder where the libraries needed to compile the PLC have
been installed.
SOLUTION
Contact our technical service department.
Summary of Contents for 8065
Page 1: ...Ref 1709 8060 8065 CNC Error solving manual...
Page 4: ...BLANK PAGE 4...
Page 216: ...Error solving manual CNC 8060 CNC 8065 216 REF 1709...
Page 217: ...Error solving manual CNC 8060 CNC 8065 217 User notes REF 1709...
Page 218: ...Error solving manual CNC 8060 CNC 8065 218 User notes REF 1709...
Page 219: ...Error solving manual CNC 8060 CNC 8065 219 User notes REF 1709...