background image

Wired Remote 

Controller

Installation Manual

MODEL  BRC1H71W 

English

+

-

• Be sure to read before conducting the installation of this product, and conduct 

installation according to this manual.

• Refer to this manual together with the installation manual of the indoor unit.

It is possible to perform settings of some functions from  

a smart phone app.

01_EN_EM19A026_IM.indd   1

2020/09/08   14:20:58

Summary of Contents for BRC1H71W

Page 1: ...onducting the installation of this product and conduct installation according to this manual Refer to this manual together with the installation manual of the indoor unit It is possible to perform set...

Page 2: ...01_EN_EM19A026_IM indd 2 2020 09 08 14 20 58...

Page 3: ...scriptions 11 Overview of screens 12 Setting screen list 13 Names and Functions 15 Starting up the system 16 Switching the Changeover Master 19 Installer Menu 23 Field Setting 24 R C Setting 28 Instal...

Page 4: ...ndicates situations that may result in equipment or property damage accidents only WARNING Only qualified personnel must carry out the installation work Consult your Daikin dealer regarding relocation...

Page 5: ...ote controller it may cause electric shock and electrical components may fail NOTE Install the control wires for the indoor unit and the remote controller at least 3 5 feet 1 meter away from televisio...

Page 6: ...t may be seen after the remote controller is installed NOTE 3 11 64 80 5 13 64 5 33 64 13 1 47 64 44 9 32 7 R3 32 2 5 R3 32 2 5 13 64 5 41 64 16 25 1 47 64 44 35 64 13 75 3 11 64 80 5 Back plate Throu...

Page 7: ...ck plate according to the following figure After removing a thin piece with a tool such as clippers remove burrs using a file etc a Wiring from top b Wiring from left c Wiring from bottom a b c CAUTIO...

Page 8: ...d mounting plate plastic with the screws for mounting plate M3 5 10 CAUTION For the installation surface select as flat a location as possible Choose a place where there is no gap between the wall and...

Page 9: ...the wire jacket and insulation To simplify the wiring maintain a 3 8 inch 10 mm difference between the length of the two conductors Cutting guideline L Wiring outlet L Top 5 5 inch 140 mm Left 4 3 in...

Page 10: ...8 English Top outlet P1P2 P1P2 terminal Rear outlet P1P2 Left outlet P1P2 01_EN_EM19A026_IM indd 8 2020 09 08 14 21 00...

Page 11: ...the top of the controller on the top of the back plate 2 Snap the bottom of the controller into place on the bottom of the back plate 3 Ensure the installation site is dust free before peeling the pr...

Page 12: ...controller circuit board is attached to the upper casing Be careful not to damage the circuit board and casing when removing the upper casing Do not touch the remote controller circuit board directly...

Page 13: ...ss this button again to turn off the system b Status indicator LED During operation the light ring around the display lights up blue red green Lights up blue Operating Blinks red Error is occurring Li...

Page 14: ...inistrator See the next page for items which can be selected 12 34 A3 01 Unit 00 This screen displays the time and the status of the remote controller and the system If an error occurs the error code...

Page 15: ...n current setting Vertical Airflow Airflow direction 2 setting Depends on current setting Ventilation Mode Ventilation mode setting Depends on current setting Ventilation Rate Ventilation rate setting...

Page 16: ...ng Clock setting Standard Temp Scale reference temperature setting About Administrator information Admin Password Administrator password setting Installer Password Installer password setting Field Set...

Page 17: ...ndoor unit on the system has the authority to change the operation mode between cool and heat i Under centralized control Displayed if the system is under the management of a multi zone controller Opt...

Page 18: ...utomatically startup If it is the first and only controller that is connected to the indoor unit it will automatically get designated as the main controller If there is a second controller it is neces...

Page 19: ...check the wiring INFORMATION After re designating a controller the system requires a power reset INFORMATION The following functions are not available for sub controllers Auto operation mode Individua...

Page 20: ...or code appears press and hold until 2 appears on the screen When the U8 error code appears press and hold until 1 appears on the screen Result A controller displaying 1 is set as main and a controlle...

Page 21: ...t as the changeover master Depending on the system this function may not be available Possible operation mode selections for a remote controller that is a changeover master or a mode follower Operatio...

Page 22: ...When multiple indoor units are connected to the same port of a branch selector unit Give the authority to choose cooling heating or auto to 1 of these remote controllers c c b b c d c b b d d a e f e...

Page 23: ...reen 73 F 74 Auto Cool 73 Room Text mode Icon mode Press and hold button for 5 seconds or longer to display the information screen Information screen 12 34 Press in that order and hold them down for 1...

Page 24: ...ing the controller of the indoor unit that you want to set as the changeover master Cool 73 Room Menu screen Operation Mode Text mode Icon mode Navigate to the Operation Mode menu Sub menu screen Cool...

Page 25: ...73 F 74 Auto Cool 73 Room Text mode Icon mode Press and hold button for 5 seconds or longer to display the information screen Information screen 12 34 Press in that order and hold them down for 10 se...

Page 26: ...erform field setting from the mobile application Sub menu screen Text mode Icon mode Mode 20 Unit 00 Enter Return Mode 20 Unit 00 a b Press or button to select Mode No and press to enter the field set...

Page 27: ...on to set the selection Sub menu screen Text mode Icon mode SW 00 Set Cancel 01 SW 00 01 b a Press or button select First Code No and then press button a First Code No b Second Code No Sub menu screen...

Page 28: ...urn to the installer menu If the setting has been changed the screen may return to the home screen without returning to the installer menu CAUTION The connection of optional accessories to the indoor...

Page 29: ...ized 5 Room temperature value reported to multizone controllers Return air thermistor Thermistor designated by 10 2 above Note 3 12 22 2 Thermo on off deadband Note 4 2 F 1 C 1 F 0 5 C 1C 01 Change ro...

Page 30: ...setting from the mobile application Sub menu screen Text mode Icon mode Mode R1 Unit Enter Return Mode R1 Unit a b Press or button to select Mode No and press to enter the field setting menu a Mode No...

Page 31: ...mode Icon mode Press or button scroll to the desired First code No and then press button to set the selection Sub menu screen SW 13 00 SW 13 00 Set Cancel Text mode Icon mode Press or button to move S...

Page 32: ...screen If the setting is not changed select Cancel or Sub menu screen Mode R3 Unit Mode R3 Unit Enter Return Text mode Icon mode Press or button move to Return or and then press button to return to th...

Page 33: ...ay Displayed Not displayed always Not displayed when stopped only R3 04 Home screen cooling heating selection authority display Displayed Not displayed always Not displayed when stopped only R3 05 Hom...

Page 34: ...he mobile application Sub menu screen Text mode Icon mode Disable 0 0 0 0 Set Cancel 0 0 0 0 a b Press or button select Enable Disable and press to perform password enable disable setting a Enable Dis...

Page 35: ...disabled Sub menu screen 1 2 3 4 Enable 1 2 3 4 Set Cancel Text mode Icon mode Press or button move to Cancel or and then press button to return to the installer menu Other Service Settings Group Addr...

Page 36: ...ications made to the equipment without the approval of manufacturer could void the user s authority to operate this equipment FCC RF Radiation Exposure Statement To comply with the FCC RF exposure com...

Page 37: ...istribution THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS AS IS AND ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND F...

Page 38: ...EM19A026 2009 HT 01_EN_EM19A026_IM indd 36 2020 09 08 14 21 12...

Reviews: