3092
'Work zone limit exceeded'
DETECTION
During execution.
CAUSE
The CNC has tried to move an axis to a position located outside the no-exit work zone.
The zone may be defined either by program or by PLC (using the work-zone related
variables).
SOLUTION
Keep the axes within the limits of the no-exit work zone. If an axis is outside the limits,
jog it in the proper direction using the jog keys.
3093
'Point inside the forbidden zone'
DETECTION
During execution.
CAUSE
The CNC has tried to move an axis to a position located inside the no-entry work zone.
The zone may be defined either by program or by PLC (using the work-zone related
variables).
SOLUTION
Keep the axes out of the limits of the no-entry work zone. If the tool is inside the
forbidden zone, deactivate that zone temporarily, jog the axis in the proper direction
until it is outside the forbidden zone and activate the no-entry zone again.
3095
End point incorrectly programmed in #GAPCTRL or #LEAP.
DETECTION
During execution.
CAUSE
During the #GAPCTRL or #LEAP instruction, the CNC cannot correct the position
after receiving a sensor signal.
SOLUTION
Check that the end point indicated in the #GAPCTRL or #LEAP instruction is correct.
3096
PWRCTRL DUTY activated in another channel.
DETECTION
During execution.
CAUSE
An attempt has been made to activate #PWRCTRL DUTY on a channel while it active
on another channel.
SOLUTION
The #PWRCTRL DUTY can only be active on one channel.
3097
PWRCTRL OUT activated in another channel.
DETECTION
During execution.
CAUSE
An attempt has been made to activate #PWRCTRL OUT on a channel while it active
on another channel.
SOLUTION
The #PWRCTRL OUT can only be active on one channel.
3098
PWRCTRL DUTY requires active PWM in the same channel.
DETECTION
During execution.
CAUSE
An attempt has been made to activate #PWRCTRL DUTY on a channel without it first
being activated for the same channel.
SOLUTION
Activate the PWM before activating #PWRCTRL DUTY.
3100
'Excessive power on the spindle detected during DMC.’
DETECTION
During execution.
CAUSE
DMC has detected excessive power consumption (drive variable TV51) during a
period of time. This may indicate that the tool has worn down, been damaged or it
has collided with the part.
SOLUTION
Check the tool and/or the programming of the deepening pass sequence and the
radial pass sequence.
3101
'Excessive power on the spindle detected during DMC. Press START to continue'
DETECTION
During execution.
CAUSE
DMC has detected that the instantaneous power (drive variable TV51) has exceeded
the target power in a preset range. This can indicate that the tool has collided with
the part, and so the CNC stops the axes, keeping the spindle turning.
SOLUTION
Check the status of the tool and the machining. The CNC allows the execution to be
resumed by pressing [START], to enter in the tool inspection mode or to finish the
execution.
3102
Non-compatible instruction with active independent movement.
DETECTION
During execution.
CAUSE
An attempt was made to execute the #HSC or #SWT instruction on an axis with
independent motion.
SOLUTION
You can not program these instructions on an axis with an independent movement.
Summary of Contents for 8065
Page 1: ...Ref 1709 8060 8065 CNC Error solving manual...
Page 4: ...BLANK PAGE 4...
Page 216: ...Error solving manual CNC 8060 CNC 8065 216 REF 1709...
Page 217: ...Error solving manual CNC 8060 CNC 8065 217 User notes REF 1709...
Page 218: ...Error solving manual CNC 8060 CNC 8065 218 User notes REF 1709...
Page 219: ...Error solving manual CNC 8060 CNC 8065 219 User notes REF 1709...