Error solving manual.
CNC 8060
CNC 8065
·160·
(R
EF
: 1709)
6032
'Error in the configuration of the CAN keyboard'
DETECTION
During execution.
CAUSE
The 165 does not respond or there are CAN communication problems.
SOLUTION
Check the version of the COMPCI and the connection through the CAN bus.
6033
The hardware configuration does not match that saved in the file
DETECTION
On system startup or during execution.
CAUSE
The hardware configuration saved in the disk is not the same as the one detected
on start-up. Possible changes in the CAN configuration that have not been saved,
undesired changes in the machine parameters, etc.
SOLUTION
In diagnosis mode, verify that the detected CAN configuration coincides with the real
one; if not, save the configuration. Otherwise, check whether the parameters have
been set wrong or there is an error in the detection of the nodes.
6034
'Reset in CAN node'
DETECTION
During execution.
CAUSE
A CAN node has been reset. The error window indicates the node number.
SOLUTION
Verify the node is properly supplied. If there are no problems at the bus, replace the
node. Contact our technical service department.
6035
'Error when initializing local I/O'
DETECTION
During system startup.
CAUSE
More local digital outputs have been configured at the CNC than there actually are.
SOLUTION
Set a maximum of 8 local digital outputs.
6036
'There is no voltage supply for local I/O'
DETECTION
During execution.
CAUSE
There is no voltage supply at the local I/O (central units ICU and MCU).
SOLUTION
Supply local I/O with 24 V.
6037
'LOOPTIME parameter not valid for CAN configuration'
DETECTION
During system startup.
CAUSE
The value of parameter LOOPTIME is too small or is wrong.
SOLUTION
Verify that the value assigned to parameter LOOPTIME is a multiple of 0.5 ms and
greater than 1.5 ms. Increase the value if the CAN configuration so advises.
6038
'Too many CAN elements in the system'
DETECTION
During system startup.
CAUSE
An element of the CAN bus exceeds the maximum permitted; number of analog
inputs or outputs, digital inputs or outputs or counters.
SOLUTION
Turn the CNC off and remove the excessive elements from the bus.
6039
'Error when enabling the PT100 input'
DETECTION
During system startup.
CAUSE
The parameters of one of the PT100 inputs have been set wrong.
SOLUTION
Check the general machine parameters NPT100 and PT100.
6040
'Error when reading the local jog'
DETECTION
During the execution of the CNC.
CAUSE
Repeated error when reading the local jog module of the central unit ICU MCU.
SOLUTION
Check the hardware and the communication between the local jog and the central
unit.
6041
'Detected keyboard configured in 15" mode'
DETECTION
After a CNC reset.
CAUSE
The CNC has detected an 8065 keyboard (qwerty or jog) configured to communicate
with versions older than V04.10.
SOLUTION
Identify the 8065 keyboards (qwerty and jog) and configured them correctly. Contact
our technical service department.
6042
'Over-current alarm'
DETECTION
The loop has detected an over-current alarm when reading the local feedback input.
CAUSE
Short-circuit at the local feedback of the CNC.
SOLUTION
Check the proper connection and signal levels of the local feedback of the CNC.
Summary of Contents for 8065
Page 1: ...Ref 1709 8060 8065 CNC Error solving manual...
Page 4: ...BLANK PAGE 4...
Page 216: ...Error solving manual CNC 8060 CNC 8065 216 REF 1709...
Page 217: ...Error solving manual CNC 8060 CNC 8065 217 User notes REF 1709...
Page 218: ...Error solving manual CNC 8060 CNC 8065 218 User notes REF 1709...
Page 219: ...Error solving manual CNC 8060 CNC 8065 219 User notes REF 1709...