CNC 8060
CNC 8065
·200·
(R
EF
: 1709)
8728
'The timer index is missing in TEN'
DETECTION
During editing.
CAUSE
The timer is missing in the TEN command.
SOLUTION
Program "TEN timer".
8729
'The timer index is missing in TRS'
DETECTION
During editing.
CAUSE
The timer is missing in the TRS command.
SOLUTION
Program "TRS timer".
8730
'Preset missing in TG'
DETECTION
During editing.
CAUSE
The preset value is missing in the TG command.
SOLUTION
Program "TG timer preset". The preset value may be a register, a symbol or a number.
8731
'The timer index and the preset are missing in TG'
DETECTION
During editing.
CAUSE
The timer and the preset value are missing in the TG command.
SOLUTION
Program "TG timer preset". The preset value may be a register, a symbol or a number.
8732
'The order of operands is inverted in TG'
DETECTION
During editing.
CAUSE
The TG command has been programmed wrong.
SOLUTION
Program "TG timer preset". The preset value may be a register, a symbol or a number.
8733
'Action instruction expected after NOT'
DETECTION
During editing.
CAUSE
Instruction missing after NOT.
SOLUTION
Program "NOT instruction".
8734
'Counter index missing in CUP'
DETECTION
During editing.
CAUSE
The counter is missing in the CUP command.
SOLUTION
Program "CUP counter".
8735
'Counter index missing in CDW'
DETECTION
During editing.
CAUSE
The counter is missing in the CDW command.
SOLUTION
Program "CDW counter".
8736
'Counter index missing in CEN'
DETECTION
During editing.
CAUSE
The counter is missing in the CEN command.
SOLUTION
Program "CEN counter".
8737
'Preset missing in CPR'
DETECTION
During editing.
CAUSE
The preset value is missing in the CPR command.
SOLUTION
Program "CPR counter preset". The preset value may be a register, a symbol or a
number.
8738
'The counter index and the preset are missing in CPR'
DETECTION
During editing.
CAUSE
The counter and the preset value are missing in the CPR command.
SOLUTION
Program "CPR counter preset". The preset value may be a register, a symbol or a
number.
8739
'The order of operands is inverted in CPR'
DETECTION
During editing.
CAUSE
The CPR command has been programmed wrong.
SOLUTION
Program "CPR counter preset". The preset value may be a register, a symbol or a
number.
Summary of Contents for 8065
Page 1: ...Ref 1709 8060 8065 CNC Error solving manual...
Page 4: ...BLANK PAGE 4...
Page 216: ...Error solving manual CNC 8060 CNC 8065 216 REF 1709...
Page 217: ...Error solving manual CNC 8060 CNC 8065 217 User notes REF 1709...
Page 218: ...Error solving manual CNC 8060 CNC 8065 218 User notes REF 1709...
Page 219: ...Error solving manual CNC 8060 CNC 8065 219 User notes REF 1709...