(R
EF
: 1709)
4000(5)
'Error when initializing the Sercos ring'
VALUE
5.
TRANSITION
3.
VALUE
35.
CAUSE
Error when resetting errors after initializing the Sercos ring.
SOLUTION
Contact our technical service department.
4001
'Parameter LOOPTIME different at the CNC and at the drive'
VALUE
Parameter value at the CNC.
VALUE
Parameter value at the drive.
AXIS
Logic number of the axis
CAUSE
Value of the parameter LOOPTIME different at the CNC and at the drive.
SOLUTION
Set it to the same at the CNC and at the drive.
4002
'Parameter OPMODE different at the CNC and at the drive'
VALUE
Parameter value at the CNC.
VALUE
Parameter value at the drive.
AXIS
Logic number of the axis
CAUSE
Value of the parameter OPMODE different at the CNC and at the drive.
SOLUTION
Set it to the same at the CNC and at the drive.
4003
'Parameter AXISMODE different at the CNC and at the drive'
VALUE
Parameter value at the CNC.
VALUE
Parameter value at the drive.
AXIS
Logic number of the axis
CAUSE
Value of the parameter AXISTYPE different at the CNC and at the drive.
SOLUTION
Set it to the same at the CNC and at the drive.
4004
'Parameter G00FEED higher at the CNC than at the drive'
VALUE
Parameter value at the CNC.
VALUE
Parameter value at the drive.
AXIS
Logic number of the axis
CAUSE
Value of the parameter G00FEED different at the CNC and at the drive.
SOLUTION
Set it to the same at the CNC and at the drive.
4005
'Following error monitoring not active at the drive'
VALUE
0.
VALUE
PP159 parameter value at the drive.
AXIS
Logic number of the axis
CAUSE
'Following error monitoring not active at the drive'
SOLUTION
Activate parameter PP159 at the drive.
4006
'Drive parameter SP100 must be 0'
VALUE
0.
VALUE
SP100 parameter value at the drive.
AXIS
Logic number of the axis
CAUSE
The drive does not have an additional command enabled.
SOLUTION
Set drive parameter SP100 to 0.
4007
'The Sercos spindle needs a gain other than 0'
VALUE
0.
VALUE
KV value at the drive.
AXIS
Logic number of the axis
CAUSE
The spindle KV is 0.
SOLUTION
Set the drive's KV to a value other than 0.
4008
'Sercos ring Error+ because the drive has been reset'
AXIS
Logic number of the axis
CAUSE
Warning that the drive has been reset.
SOLUTION
Ignore voluntary resets of the drive with the reset button, WinDDS (recording the
version, soft reset) or hardware problems at the drive. If the error persists, contact
the Service Department.
Summary of Contents for 8065
Page 1: ...Ref 1709 8060 8065 CNC Error solving manual...
Page 4: ...BLANK PAGE 4...
Page 216: ...Error solving manual CNC 8060 CNC 8065 216 REF 1709...
Page 217: ...Error solving manual CNC 8060 CNC 8065 217 User notes REF 1709...
Page 218: ...Error solving manual CNC 8060 CNC 8065 218 User notes REF 1709...
Page 219: ...Error solving manual CNC 8060 CNC 8065 219 User notes REF 1709...