332
Error Code Lists
Section 11-5
Data transfer
Write transfer:
number of
words error
8310
The number of write words was set to 0 or
exceeded the number of write data words.
The parameters for the origin search high
speed and the origin search proximity
speed were not sent together.
Execute the
command again
after changing
the incorrect set-
ting.
The current
START com-
mand will not be
executed, but
other operating
axes will not be
affected.
Write transfer:
source word
error
8311
The write source word or the write source
area was outside the settable range.
Write transfer:
destination
address error
8312
The write destination address was outside
the settable range.
Read transfer:
number of
words error
8320
The number of read words was set to 0 or
exceeded the number of read data words.
Read transfer:
source address
error
8321
The read source address was outside the
settable range.
Read transfer:
destination
word error
8322
The read destination word or the read des-
tination area was outside the settable
range.
Error counter
reset/
Origin adjust-
ment output
Error counter
reset/
Origin adjust-
ment output
error
8400
There was an attempt to output a error
counter reset/origin adjustment output
when the output couldn’t be used.
Execute the
command again
after checking
that the output
can be used and
changing the lad-
der program if
necessary.
The axis will be
decelerated to a
stop. Other oper-
ating axes will
not be affected.
Override
Override error
8500
The override setting was outside the setta-
ble range (1 to 999%).
Execute the
command again
after correcting
the data.
Positioning
Positioning
timer timeout
8600
The Servo Drive’s positioning completed
signal did not go ON within the axis
parameters’ specified time.
Execute the
command again
after making
adjustments
such as adjust-
ing the position-
ing monitor time
or the servo sys-
tem’s gain, or
checking the wir-
ing for the posi-
tioning
completed sig-
nal and correct-
ing if necessary.
The designated
axis will be
decelerated to a
stop.
Other operating
axes will not be
affected.
Overflow
8601
The movement distance is too long
(greater than 2,147,483,646 pulses, or
greater than 2,147,483,520 pulses for lin-
ear interpolation) and so operation is not
possible.
Execute the
command again
after reducing
the distance to
move in one
operation (by
changing the
position data).
The designated
axis will be
decelerated to a
stop.
Other operating
axes will not be
affected.
Group
Name
Code
Cause
Clearing
method
Operation after
error
Содержание CS1W-213 - REV 02-2008
Страница 1: ...Position Control Units Cat No W376 E1 06 SYSMAC CS1W NC113 213 413 133 233 433 OPERATION MANUAL ...
Страница 2: ...CS1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Страница 3: ...iv ...
Страница 13: ...xiv ...
Страница 15: ...xvi ...
Страница 19: ...xx ...
Страница 43: ...18 Basic Operational Flow Section 2 1 ...
Страница 87: ...62 Servo Relay Unit Section 3 7 ...
Страница 199: ...174 Z phase Margin Section 6 8 ...
Страница 217: ...192 Sample Program Section 7 7 ...
Страница 285: ...260 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Страница 377: ...352 Common Parameter Area Appendix C ...
Страница 395: ...370 Parameter Coding Sheets Appendix F ...