141
Saving Data
Section 5-6
• Axis parameters
• Positioning sequences
• Speeds
• Acceleration and deceleration times
• Dwell times
• Zones
Note
The data for the number of axes for the particular PCU being used is all saved
at once.
Parameters and other data that have been saved to flash memory are read to
the PCU’s internal memory when the PCU is powered up or restarted. If the
parameters or other data are corrupted at that time, a parameter destruction
error (error code 0001) or data destruction error (error code 0002) will be gen-
erated and the PCU will be started up using the initial values (i.e., the factory
settings) or the parameters and data that had been saved prior to the last
save to flash memory.
If parameters or data are lost, no operation other than data transfer or data
saved can be received. After transferring the data, save the data and turn the
power OFF and then ON again, or restart the PCU.
5-6-2
Data Saving Procedure
Data can be saved using either the SAVE DATA Bit in the operating memory
area or using CX-Position. For details of saving data using CX-Position, refer
to the CX-Position Operation Manual (W433).
Beginning Words of Operating Memory Area, Operating Data Area, and
Parameter Areas
The beginning words of the operating memory area, the operating data area
and common parameter area used for a PCU are determined (or set) accord-
ing to the following.
• Beginning word of the operating memory area, n = CIO 2000 + 10
×
unit
number
• Beginning word of the common parameter area, m = 100
×
unit
number
• Beginning word of the operating data area, l, is specified in m and m+1.
Word
Name
Bit
Reference
m
Operating data area
designation
00 to 15
SECTION 4
m+1
Beginning word of
operating data area
00 to 15
m+2
Axis parameter
designation
00 to 15
Содержание CS1W-213 - REV 02-2008
Страница 1: ...Position Control Units Cat No W376 E1 06 SYSMAC CS1W NC113 213 413 133 233 433 OPERATION MANUAL ...
Страница 2: ...CS1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Страница 3: ...iv ...
Страница 13: ...xiv ...
Страница 15: ...xvi ...
Страница 19: ...xx ...
Страница 43: ...18 Basic Operational Flow Section 2 1 ...
Страница 87: ...62 Servo Relay Unit Section 3 7 ...
Страница 199: ...174 Z phase Margin Section 6 8 ...
Страница 217: ...192 Sample Program Section 7 7 ...
Страница 285: ...260 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Страница 377: ...352 Common Parameter Area Appendix C ...
Страница 395: ...370 Parameter Coding Sheets Appendix F ...