6F2S1915 (0.46)
GRZ200 (Soft 031 & 032)
- 285 -
2.17.4
Data ID
Signal monitoring point
FRQ(Function ID: 475001)
Element ID
Name
Description
8400101B61
DFRQ-OPT-ALARM
Alarm signal by DFRQ protection
8300101B23
DFRQ-OPT-TRIP
Trip signal by DFRQ protection
8100111B61
DFRQ-S1-ALARM
Alarm signal by DFRQ1 protection
8000111BB1
DFRQ-S1-OPT
DFRQ1 protection operated
8000111B23
DFRQ-S1-TRIP
Trip signal by DFRQ1 protection
8100121B61
DFRQ-S2-ALARM
Alarm signal by DFRQ2 protection
8100121BB1
DFRQ-S2-OPT
DFRQ2 protection operated
8000121B23
DFRQ-S2-TRIP
Trip signal by DFRQ2 protection
8100131B61
DFRQ-S3-ALARM
Alarm signal by DFRQ3 protection
8200131BB1
DFRQ-S3-OPT
DFRQ3 protection operated
8000131B23
DFRQ-S3-TRIP
Trip signal by DFRQ3 protection
8100141B61
DFRQ-S4-ALARM
Alarm signal by DFRQ4 protection
8300141BB1
DFRQ-S4-OPT
DFRQ4 protection operated
8000141B23
DFRQ-S4-TRIP
Trip signal by DFRQ4 protection
8100151B61
DFRQ-S5-ALARM
Alarm signal by DFRQ5 protection
8400151BB1
DFRQ-S5-OPT
DFRQ5 protection operated
8000151B23
DFRQ-S5-TRIP
Trip signal by DFRQ5 protection
8100161B61
DFRQ-S6-ALARM
Alarm signal by DFRQ6 protection
8500161BB1
DFRQ-S6-OPT
DFRQ6 protection operated
8000161B23
DFRQ-S6-TRIP
Trip signal by DFRQ6 protection
8000111C23
DFRQ1
DFRQ1 relay element operated
8000111B60
DFRQ1-OPT
DFRQ1 element operated
8000111BB0
DFRQ1_BLOCK
DFRQ1 protection block command
8100121C23
DFRQ2
DFRQ2 relay element operated
8100121B60
DFRQ2-OPT
DFRQ2 element operated
8100121BB0
DFRQ2_BLOCK
DFRQ2 protection block command
8200131C23
DFRQ3
DFRQ3 relay element operated
8200131B60
DFRQ3-OPT
DFRQ3 element operated
8200131BB0
DFRQ3_BLOCK
DFRQ3 protection block command
8300141C23
DFRQ4
DFRQ4 relay element operated
8300141B60
DFRQ4-OPT
DFRQ4 element operated
8300141BB0
DFRQ4_BLOCK
DFRQ4 protection block command
8400151C23
DFRQ5
DFRQ5 relay element operated
8400151B60
DFRQ5-OPT
DFRQ5 element operated
8400151BB0
DFRQ5_BLOCK
DFRQ5 protection block command
8500161C23
DFRQ6
DFRQ6 relay element operated
8500161B60
DFRQ6-OPT
DFRQ6 element operated
8500161BB0
DFRQ6_BLOCK
DFRQ6 protection block command
8400001B61
FRQ-OPT-ALARM
Alarm signal by FRQ protection
8300001B23
FRQ-OPT-TRIP
Trip signal by FRQ protection
8100011B61
FRQ-S1-ALARM
Alarm signal by FRQ1 protection
8000011BB1
FRQ-S1-OPT
FRQ1 protection operated
8000011B23
FRQ-S1-TRIP
Trip signal by FRQ1 protection
Summary of Contents for GR 200 Series
Page 1047: ...6F2S1915 0 46 GRZ200 Soft 031 032 1026 Figure 8 3 4 Screen shot from GR TIEMS ...
Page 1354: ...6F2S1915 0 46 GRZ200 Soft 031 032 1333 Appendix 1 Signal list for common function ...
Page 1410: ...6F2S1915 0 46 GRZ200 Soft 031 032 1389 This page is intentionally blank ...
Page 1480: ...6F2S1915 0 46 GRZ200 Soft 031 032 1459 Appendix 6 Ordering ...
Page 1497: ...6F2S1915 0 46 GRZ200 Soft 031 032 1476 Appendix 7 Technical data ...
Page 1518: ...6F2S1915 0 46 GRZ200 Soft 031 032 1497 Appendix 8 Manufacture setting ...
Page 1523: ...6F2S1915 0 46 GRZ200 Soft 031 032 1502 Appendix 10 CT requirement ...
Page 1531: ...6F2S1915 0 46 GRZ200 Soft 031 032 1510 Appendix 12 Engineering exercise ...
Page 1563: ......