Capture Module - Control and Status Registers
842
SPRUHE8E – October 2012 – Revised November 2019
Copyright © 2012–2019, Texas Instruments Incorporated
C28 Enhanced Capture (eCAP) Module
Table 8-8. ECAP Control Register 2 (ECCTL2) Field Descriptions (continued)
Bit(s)
Field
Description
10
Stop after Capture Event 3 in one-shot mode
Wrap after Capture Event 3 in continuous mode.
11
Stop after Capture Event 4 in one-shot mode
Wrap after Capture Event 4 in continuous mode.
Notes: STOP_WRAP is compared to Mod4 counter and, when equal, 2 actions
occur:
• Mod4 counter is stopped (frozen)
• Capture register loads are inhibited
In one-shot mode, further interrupt events are blocked until re-armed.
0
CONT/ONESHT
Continuous or one-shot mode control (applicable only in capture mode)
0
Operate in continuous mode
1
Operate in one-Shot mode