MII Management Register Descriptions
1441
SPRUHE8E – October 2012 – Revised November 2019
Copyright © 2012–2019, Texas Instruments Incorporated
M3 Ethernet Media Access Controller (EMAC)
19.7.2 Ethernet PHY Management Register 1 – Status (MR1) Register, address 0x01
This register enables software to determine the capabilities of an external PHY and perform its
initialization and operation appropriately.
Figure 19-22. Ethernet PHY Management Register 1 – Status (MR1) Register
15
14
13
12
11
10
8
Reserved
100X_F
100X_H
10T_F
10T_H
Reserved
R-0
R-1
R-1
R-1
R-1
R-0
7
6
5
4
3
2
1
0
Reserved
ANEGC
RFAULT
ANEGA
LINK
JAB
EXTD
R-0
R-0
R-0
R-0
R-0
R-C
R-0
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 19-21. Ethernet PHY Management Register 1 – Control (MR1) Register Field Descriptions
Bit
Field
Value
Description
15
Reserved
1
Reserved
14
100X_F
100BASE-TX Full-Duplex Mode
0
The Ethernet PHY is not capable of supporting 100BASE-TX Full-Duplex mode.
1
The Ethernet PHY is capable of supporting 100BASE-TX Full-Duplex mode.
13
100X_H
100BASE-TX Half-Duplex Mode
0
The Ethernet PHY is not capable of supporting 100BASE-TX Half-Duplex mode
1
The Ethernet PHY is capable of supporting 100BASE-TX Half-Duplex mode.
12
10T_F
10BASE-T Full-Duplex Mode
0
The Ethernet PHY is not capable of supporting 10BASE-T Full-Duplex mode.
1
The Ethernet PHY is capable of supporting 10BASE-T Full-Duplex mode.
11
10T_H
10BASE-T Half-Duplex Mode
0
The Ethernet PHY is not capable of supporting 10BASE-T Half-Duplex mode.
1
The Ethernet PHY is capable of supporting 10BASE-T Half-Duplex mode.
10-6
Reserved
Reserved
5
ANEGC
Auto-Negotiation Complete
0
The auto-negotiation process is not complete.
1
The auto-negotiation process has been completed and that the extended registers defined by the
auto-negotiation protocol are valid.
4
RFAULT
Remote Fault
0
A remote fault condition has not been detected.
1
A remote fault condition has been detected.
This bit remains set until it is read, even if the condition no longer exists.
3
ANEGA
Auto-Negotiation
0
The Ethernet PHY does not have the ability to perform auto-negotiation.
1
The Ethernet PHY has the ability to perform auto-negotiation.
2
LINK
Link Made
0
A valid link has not been established by the Ethernet PHY.
1
A valid link has been established by the Ethernet PHY.
1
JAB
Jabber Condition
0
A jabber condition has not been detected by the Ethernet PHY.
1
A jabber condition has been detected by the Ethernet Controller
This bit remains set until it is read, even if the jabber condition no longer exists.
0
EXTD
Extended Capabilities
0
The Ethernet PHY does not provide extended capabilities
1
The Ethernet PHY provides an extended set of capabilities that can be accessed through the
extended register set.